How to exactly synchronize a camera and LOG-1

If there is some misalignment between the time held by the camera and LOG-1, please set the time again before using LOG-1.  (See: Set device time)

Also, in order to more accurately synchronize the video and sensor data, please follow the steps below before recording a video.

Steps

  1. Start recording using the camera.
  2. Shoot a scene where the LOG-1 LED is facing the camera.

    If you had already attached both the camera and LOG-1, record a scene where the LOG-1 switch is pressed.
    (For example, the measurement starts after the LED turns off. So first hold your hand in front of the camera and then move your hand as soon as the LED goes out.)

    *This step will synchronize video and sensor data before movie editing.
  3. Please stand the bicycle or other device you have attached LOG-1 to upright for a few seconds.
    Log-1_read_calibration_stay
    *This step will detect gravity direction and calibrate LOG-1 before movie editing.
  4. If possible, tilt the bicycle or other device you have attached LOG-1 to, left and right slowly for a few seconds.
    Log-1_read_calibration_tilt
    *This step is useful for checking whether synchronization and calibration are correct before editing movies.
  5. Continue recording the movie.
    *As you can clip the start and end range of the movie during movie editing, the previous calibration steps can be easily removed from the final video.

When preparation for synchronization is not possible before recording or when there is a period of time between attaching LOG-1 and recording a movie.

Please record a video separately for synchronizing and another for the actual video you want to use.

  1. Take a short video showing LOG-1 switching ON. After that, will LOG-1 continue to log data (data can be logged continuously for 19 hours).
  2. When recording the final movie, use the same camera as in step 1 and take a static video for a few seconds to detect default position.
  3. After all the shots are finished, switch off LOG-1.
  4. When editing the movie, detect the time lag between the camera and LOG-1 by using the video for synchronization and take a note of the sync correction value.
  5. Select the final movie and enter the value noted in step 4 for synchronization. Synchronization can be adjusted in 0.1 second increments.

LED Indicator on LOG-1

LED Indication Patterns for LOG-1 Status

Please check the following table for LOG-1’s status via its LED indicator.

Logging Mode Sleep Mode
Normal Green (Blink) Off
Without Setting Time ※1 Green (Blink High Freq.)
No Battery (Approx. 2.0V or Less) ※2 Red
Low Battery (Approx. 2.0V~2.1V) Red (Blink High Freq.)
Low Memory Orange / Green (Blink Alternately)
  • Blink : Every 3 sec
  • Blink High Freq. : Every 0.5 sec
  • ※1 : Will not notify “Without Setting Time” error during logging mode.
  • ※2 : Logging will stop if battery runs out.

LED Indication Patterns During User Operation

Please check the following table for the LED indication patterns during user operation.

Behavior Operation LED Pattern Remarks
Start Logging Press 3 sec Green 3 sec The LED turns green for 3 seconds. Logging starts moment the LED turns off.
Magnet Detection Mode Click twice Press the button twice quickly to enter magnet detection mode. After 20 seconds the device will automatically exit magnet detection mode and return to sleep mode.
Not Detected Green
Detected Red
Connected to PC Application
Configured with PC Application
Green Blink twice Blinks when connected to PC application or configured via the PC application.
Erase Data Click 5 times / Erase with PC App Orange

Magnet Detection Mode

Press the button twice quickly in standby mode to enter magnet detection mode. In this mode, the LED will turn from green to red when detecting a magnetic force. After 20 seconds the device will automatically exit magnet detection mode and return to sleep mode.

NOTE
You can not log data or communicate with a PC in this mode.

Logging Mode

Start / Stop Logging

Press and hold the button for more than 2 seconds in standby mode to start logging.
Press and hold the button for more than 2 seconds while logging and the LED will blink twice and stop logging.
If connected to a PC or the battery runs out while logging, the device will stop logging.

While Logging

The device will log according to the set sampling settings.
While logging, the LED will blink indicating the status of the device. (For more details, please refer to this page.)

Sampling Settings

You can set sampling settings via the PC application.
For details, please refer to the section “Sensor Options” on this page.

The factory default setting is as follows.

Sampling Ratio 12.5Hz (Every 80ms)
Magnetic Force Detection Feature Enabled
NOTE
・The maximum number of separate logs is 64.
(If 64 separate logs are stored on the device, please extract and erase all data before starting additional logs.)
・The maximum logging duration depends on the sampling setting.
(Under factory default settings and 100% battery level, the device can log for approximately 19 hours. For details, please refer to this page.)

Operation of LOG-1

Overview

Modes

Modes Functions
Standby When the device has no tasks, it will enter this mode and save battery power.
Magnetic Force Detection Mode Detect magnetic force via LED notification. Please use this feature for magnet installation.
Logging Mode Get data from sensors and write logs.
Communicate with a PC Extract data or set sampling settings via the PC application.

Operation Under Standby Mode

Behavior Operation Details
Start Logging Press and hold the button for more than 2 sec. The LED will turn to green 3 seconds and start logging.
Magnetic Force Detection Mode Press the button twice. Detect magnetic force via LED notification.
Erase Data Press the button 5 times. Erase all log data from the device. While erasing, the LED will turn orange.
Communicate with a PC Connect to a PC Communicate with a PC.
NOTE
・Erased data can not be recovered.
・Do not disconnect the cable or remove the battery while erasing data.
・The device will not accept any operations if the battery runs out.

Behavior while in Sleep Mode

The device will enter sleep mode when it has no tasks.
While sleep mode, the device will keep time and indicate status of LOG-1 via the LED.
For details about the LED indicator, please refer to this page.

NOTE
・Device can not be powered off completely.

Device Setup

Setup instructions

To use the gyro function effectively, please attach in a position where the direction indicator mark faces forward.

The direction indication mark must face the traveling direction, it can be at any angle as long as the mark faces forward.

If the direction of travel and the direction indication mark are not aligned, the gyro function can not be used correctly.

Magnet Setup

Attach so that the magnet can be detected at the magnetic force detection area. Refer to “Magnetic Force Detection Mode” for confirming whether the magnet is detected correctly at the installed position.

Attach the magnets using the fixing holes. The fixing hole can pass through a tie up to 4.8 mm in width and 1.3 mm in thickness.

How to Use the Mounting Bracket

Align the bolt and the nut, then turn the bolt to fix LOG-1 and the mounting bracket.
You can install parallel to the mounting bracket by aligning the lug on the mounting bracket.

Set device time

LOG-1 sensor data and videos captured by the camera are combined in the PC application. In order to prevent the mismatched video and sensor data, you will need to match both the time of the camera and LOG-1 before sensor data acquisition.

Please note, the camera and LOG-1 may not be able to synchronize exactly via setting the device time. Please see [How to synchronize exactly] for a more accurate method of synchronization.

Adjust the time on the camera

Please refer to the time adjustment in accordance with the instructions of the camera being used.
If you are using REC-1, you can set the time by connecting LOG-1 and REC-1. Please refer to the REC-1 manual page for more information.

Adjust the time on LOG-1

  1. Install the application on a PC.
    (Click here for how to install.)
  2. Insert a button battery into LOG-1. If time has not been set before, the LED will flash green.
    (Click here for how to insert the battery.)
  3. Remove the front cover of the main body and connect to a PC.
    (Click here for how to connect.)
  4. Start the XON LOG-1 Utility.
    Log-1_utirity_home
  5. Connect LOG-1 to the PC, and click “Scan Device”.
    Log-1_utirity_scan_device
  6. If a device is recognized, click “OK”.
    Log-1_utirity_scan_device_ok
  7. Click “Set Device Time” to set the time.
    Log-1_utirity_set_device_time
  8. Click the “OK” button.
  9. Confirm that the LED is not blinking and click the “Close” button to close the Utility.

Connecting with a PC

  1. Remove the rubber cap and connect to a PC with the supplied Micro USB cable.
  2. To disconnect from a PC, remove the USB cable and attach the rubber cap again.
NOTE
・If the rubber cap is not installed properly, there is a danger of water entering the device.
・Batteries cannot be charged via USB power.
・Features (such as logging etc.) cannot be used when connected to a PC.
・Please use the device under USB 1.1.

Battery Installation

  1. Loosen the screw and remove the battery cover.
  2. Please insert the battery cell so that the plus side of the battery cell is facing the cover.
  3. After inserting the battery cell, attach the battery cover again and tighten the screw.
NOTE
・If the battery cover is not installed properly, there is a danger of water entering the device.
・Inserting the battery incorrectly may damage the equipment.
・Battery life is typically about 1 week during recording, about 2 weeks in sleep mode.
・Please be careful not to lose the screw of the battery cover.
・When loosening the screw, please use a number 0 Phillips screwdriver. (If you use an incorrect screwdriver you may cause damage to the screw head)

Install PC applications

Application download

Please download from this link and install.

Application PC Requirements

LOG-1 uses Windows applications for changing device settings and exporting movies.
PCs that meet the following specifications are required to use this product.

Components Specifications
OS Windows 8.1 / Windows 10 (recommended)
Memory 2GB (4GB or more recommended)
HDD free space (for installation) 1GB or more
Graphics DirectX11 or greater
USB port USB 1.1 or higher (1.1 / 2.0 / 3.0)
Display 960×768 or higher
  • Operation is not guaranteed for all PC environments.
  • The above OS must be installed at factory shipment.
  • We can not guarantee the operation in the multi-boot environment.
  • Other applications may affect operation.
  • Depending on the content of the work, the required PC specifications differ.
  • It is recommended to use various drivers with the latest version.
  • Company name, product name, service name listed are trademarks or registered trademarks of each company

How to download and install applications

  1. Open “XonLog1_Setup_1.x.x.exe” with administrative privileges.
  2. Read the application licensing terms link (software license) and check the check box, then click the install button.
    Log-1_application_install
  3. Click on “Yes” to confirm.
  4. Installation will begin. (Installation time may vary depending on the speed of your PC)
  5. When the installation is complete click “Close”.
  6. Shortcut icons for the two applications will be displayed on the desktop.

LOG-1 Applications

XON LOG-1 Utility

Application for extracting and deletion of LOG-1 of settings and data.

XON LOG-1 Overlay Movie Exporter

Application for combining data LOG-1 has obtained and overlaying data onto recorded video.

XON LOG-1 Date Correction

This application can be used to correct the date and time of videos/LOG-1 files.